470 Series    SAE Threaded Cartridge Excess Flow Protectors (installed with Allen wrench)

                                                                                                                                                                                                    

Material All steel construction. 
Closing Flow  Preset by factory to customer specified value (tolerance: +20%/-0%). Standard flow after valve closes is approximately 1.5 gpm at a pressure drop of 1500 psi. Contact the factory for special bleed flow requirements. 
Pressure 3,000 psi maximum
Pressure Differential 50 to 100 psi
Fluid General hydraulic fluid
Seals Not applicable
Operating Temp. Not applicable

 

DIMENSIONS      [For Prices Click Here]
Model No. Flow Range  "A" (Hex) "B" "C" Thread Size
470-T4-XX .5 - 2 GPM 3/16" .75" 7/16-20 unf
470-T6-XX .5 - 8 GPM 3/16" .75" 9/16-18 unf
470-T8-XX 1 - 20 GPM 5/16" .79" 3/4-16 unf
470-T10-XX 2 - 30 GPM 3/8" .79" 7/8-14 unf
470-T12-XX 2 - 45 GPM 7/16" .96" 1 1/16-12 un

 

("XX" in the model no. is the closing flow specified by the customer in gallons per minute.) 

Logic Hydraulic Controls, Wilmington, North Carolina    