412 Series Male PF x Male PF 30 Degree Flare Excess Flow Protectors
|
Material |
All steel construction. Yellow zinc finish. |
|
Closing Flow |
Preset by factory to customer specified value (tolerance: +20%/-0%). Standard flow after valve closes is approximately 3.0 gpm at a pressure drop of 1500 psi. Contact the factory for special bleed flow requirements. |
|
Pressure |
3,000 psi maximum |
|
Pressure Differential |
200 to 300 psi |
|
Fluid |
General hydraulic fluid |
|
Seals |
Buna-N |
|
Operating Temp. |
-40 degrees F to +200 degrees F |
|
DIMENSIONS [For Prices Click Here] |
||||||
|
Model No. |
Inlet |
Outlet |
Flow Range |
"A" (Hex) |
"B" |
"C" |
|
412-03-XX |
PF 3/8 |
PF 3/8 Flare |
5 - 20 GPM |
7/8" |
2.03" |
.97" |
|
412-04-XX |
PF 1/2 |
PF 1/2 Flare |
5 - 35 GPM |
1 1/16" |
2.43" |
1.29" |
("XX" in the model no. is the closing flow specified by the customer in gallons per minute.)
|
Logic Hydraulic Controls, Wilmington, North Carolina |
|